Service Hotline
135-0535-2885
市 場(chǎng) 價(jià):¥0
優(yōu) 惠 價(jià):¥1
庫(kù) 存:0
PRODUCT DESCRIPTION:
VpCI®-396 is a fast drying, solvent-based moisture cure urethane one coat system (primer & topcoat) that can be applied DTM (Direct to Metal) and provides protection in harsh, outdoor, unsheltered applications.
The complex mixture of non-toxic, organic inhibitors offers protection that competes with most paints and zinc-rich primers. Provides multi-metal protection. Can be matched to most custom colors.
Volume Solids
56.20%
Gloss (ASTM D532)
30-50
VOCs (ASTM D3960)
3.1 lbs/gal (371 g/l)
Viscosity
55-65 sec+ Zahn#3
Pencil Hardness (ASTM D3363)
2H
Spreading Rate
901 sq.ft/gal @ 1.0 mils DFT
(22.1 sq.m/l @ 25 μm)
Weight per Gallon
9.39 lbs/gal (1.13 kg/l)
Flash Point
77°F (25°C)
Recommended DFT
2.0-3.0 mils (50-75 μm)
Recommended WFT
3.5-5.3 mils (88-130 μm)
Dry to Touch
2-3 hrs
Dry to Handle
4-6 hrs
Recoat Time
Dry to touch - 72 hrs, sand thereafter
Force Dry
15-20 min @ 150°F (65°C)
Full Cure
3-7 days
Salt Spray (ASTM B117)
750 hrs
Humidity (ASTM D1748)
1000 hrs
Adhesion (ASTM D3359)
5B
Flexibility (ASTM D522)
1/2" mandrel (1.27cm)
PACKAGING & STORAGE
VpCI®-396 is available in 5 gallon (19 liter) pails. Partially used containers must be purged with nitrogen.
Product shelf life is 1 year.
CHARACTERISTICS/TECHNICAL DATA
APPLICATION
Surface Preparation
Substrate should be free of grease, oil, dirt, fingerprints, drawing compounds, rust inhibitors, or any other surface contam- ination that could affect adhesion. For production line applications, use VpCI-440 or similar phosphatizing pre-treatment. For structural steel applications, Cortec® recommends a minimum of a NACE #3/ SSPC-SP6 commercial blast clean. Consult Cortec® Technical Service and/or test system adhesion prior to full scale application.
A wash primer such as VpCI-373 green applied at 0.5-1.0 mils (12.5-25 microns) is recommended before applying the VpCI®- 396 to aluminum, galvanized or plated substrates. When solvent based topcoats are applied over VpCI-396, compatibility must be checked. Cortec® recommended topcoats include VpCI®-280, 380, 381, 386, 387, 390, 392, 382, and 384.
Note: Make sure dew point is more than 5°F (2°C) less than air temperature for application. Humidity must be min. 20%, max. 80%. Power agitate to a uniform consistency using a “squirrel cage” type mixer, hand-held drill mixer, or other equivalent method. VpCI®-396 can be applied by spray, roll, brush, or dip
Typical Equipment Setups
HVLP / Conventional Spray
?Tip .009”-.021” *dependent upon pressures and viscosity
?Air Pressure 45-55 psi
?Fluid Pressure 10 psi
?Fluid hose should be 3/8” (0.95 cm) I.D. with a maximum length of 50 feet (15.2 m). Pot should always have dual regula- tion and be kept at same elevation as spray gun.
Air Assisted Airless / Airless
?Tip .015”-.035” *dependent upon pressures and viscosity
?Pressure 1800-2500 psi
?Hose should be 3/8” (0.95 cm) I.D. minimum, but a ?”
?(0.64 cm) I.D. whip end section may be used for ease of application. A maximum length of 100 feet (30.5 m) is suggested.
Cleanup
Clean tools/equipment immediately after use with Butyl Acetate when paint is still wet. When dry, use Butyl Cellusolve or MEK. Follow mfg’s safety recommendations when using any solvent.
Qingdao Cortec Rust Proof Materials Co., Ltd.,
Consultation hotline:0532-80989502
Sales Hotline:135-0535-2885
E-mail:zzgvci@163.com
QQ:592192408
Address:Room 2073, No. 12, chongmingdao East Road, Qingdao Economic Development Zone
Alibaba store:https://shop1420649126784.1688.com